Slow speed operation of fan systems within the air handling industry is generally performed due to two reasons: a coast down operation is required for hot (induced draft) fans to cool down before shutdown (often by using a turning gear), and operational efficiency improvements can be achieved during non-peak periods by slow speed operation using a VFD. In either case, when these fans are supported by hydrodynamic bearings, it is the oil film thickness developed from the bearing-shaft interaction that limits the minimum speed that can be maintained without causing premature wear and bearing failure. This paper will present a brief overview of lubrication theory and critical design parameters to achieve slow speed operation.